Tianjin tianbo glass, wholesale supplier of Wired Laminated Fire-Resistant Glass Panel, provides project-based production.Glass thickness 4-80mm. The embedded wire mesh and laminated interlayer work together to hold fragments, resist impact and block flames and smoke, supporting fire-rated partitions, doors and windows. Reliable installation and stable performance are ensured.
Tianjin Tianbo Glass is a professional manufacturer and supplier of Wired Laminated Fire-Resistant Glass Panels for commercial buildings, industrial facilities and public spaces. The product combines multiple glass layers, embedded wire mesh and fire-resistant interlayers to help maintain panel integrity under high temperatures. When exposed to heat, the fire-resistant interlayer can expand to form an insulating barrier that helps limit the spread of flames and smoke. The wired laminated structure also helps retain glass fragments after breakage, reducing the risk of falling pieces. It is suitable for fire-rated doors, corridor partitions, stairwell windows, factory fire separation systems and escape routes where both visibility and fire protection are required. Panel dimensions, thickness and edge processing can be customized according to project drawings and frame requirements.
What is it
Wired Laminated Fire-Resistant Glass Panel is a fire-rated laminated glazing product designed for building fire safety applications. It combines multiple glass layers with fire-resistant interlayers that expand under heat to form an insulating barrier, helping block flames and smoke while supporting safe evacuation. The laminated structure also helps hold broken fragments in place, reducing the risk of flying glass and secondary injury. It is suitable for fire-rated doors, corridor partitions, stairwell windows, factory firewalls and escape route glazing where both visibility and fire protection are required. The panel can be customized in size, thickness and edge finish to match different frame systems and project requirements.
Advantage
Fire and flame retardant, smoke and flame barrier: Wired Laminated Fire-Resistant Glass Panel is composed of multi-layer glass and fireproof intermediate layer. When heated, the intermediate layer expands to form a barrier layer, which helps to block the spread of flame and high temperature smoke, and secure time for fire compartment and evacuation passage.
Debris retention and reduction of secondary damage: the sandwich structure can adhere the debris to the original position in case of impact and fracture, reduce the damage caused by glass splashing, give consideration to fire safety and daily use safety, and be suitable for fire doors, partitions and escape routes.
Transparent and visible, taking into account the space lighting: While meeting the fire protection requirements, keep good light transmittance, facilitate the building lighting, visual separation and daily inspection, applicable to shopping malls, hospitals, schools, transportation hubs and other places with requirements for the permeability and fire zoning.
Support customization and adapt to different frame systems: the size, thickness, fire rating and edge treatment can be customized according to the project requirements. The hole position and gap are processed before the lamination. The size is stable and convenient for installation. It supports the batch supply of the project.
Product specification
Shape
Flat
Structure
Solid
Function
Insulated Glass, Low-E Glass, Heat Reflective Glas
Melting Point
High Temperature
Color
Clear
Product Name
LaminatedFire-Resistant Glass
Glass Type
Tempered
MOQ
1*40 FCL
Transport Package
Wooden Crates, Container
Appearance
Flat
Layer Type
Common Laminated Glass
Usage
Furniture, Door, Building, Window
Keywords
Plyglass
Thickness
Customizable on Request
Application
Architecture, Furniture
Custmized
Customized
Origin
China
Recommendations for model selection
First, confirm the fire rating and the use part: different building parts have different requirements on fire integrity and thermal insulation performance. When selecting WiredFire-Resistant Glass Panel, first specify the fire rating, test standard and installation position (fire door, partition, corridor window, etc.) required by the project, and then confirm the number of glass layers, middle layer configuration and overall thickness, so as to avoid only selecting the model according to the unit price.
Determine the size according to the frame system and installation node: the fireproof glass shall match the fireproof door frame, partition profile and sealing system. The opening size, frame type and installation node shall be provided during type selection, and the size, edge treatment and reserved clearance of glass pieces shall be confirmed to ensure continuous sealing and stable stress after installation without affecting the fire resistance.
Focus on matching wire mesh to sandwich structure: Wire mesh in WiredFire-Resistant Glass Panel helps fix chips and improve mechanical strength, but mesh size, sandwich type and glass thickness need to be matched. When purchasing, the manufacturer can be required to specify the screen material, mesh number and interlayer configuration, and the comprehensive evaluation shall be carried out in combination with the impact resistance and fire protection requirements.
Processing requirements and certification data shall be confirmed in advance: hole location, notch and special-shaped edge shall be processed before lamination, and secondary cutting is not allowed after tempering or lamination. At the selection stage, the processing drawings, acceptance standards and fire test report requirements shall be confirmed together. Check whether the certification scope is consistent with the order specification, and then arrange the lofting or batch production.
HOW TO MAINTAIN
Neutral cleaner for daily cleaning: when cleaning the WiredFire-Resistant Glass Panel, remove the dust on the surface with soft cloth or sponge, and then wipe it with neutral cleaner and clean water. Avoid using strong acid, strong alkali, grinding powder or steel wire ball to prevent damaging the glass surface and edge seal. Do not scratch the wire mesh area with sharp tools to avoid damaging the sandwich structure.
Regularly check the state of edge sealing and interlayer: check whether the sealant around the glass is cracked, debonded or aged, and whether there is bubble, atomization or water in the interlayer. The edge sealing of fireproof glass directly affects the fireproof performance. In case of any abnormality, contact the manufacturer for evaluation and treatment. Do not disassemble or repair it by yourself.
Avoid impact and improper stress: prevent hard objects from hitting glass corners during use. Do not hang heavy objects or randomly open holes on the glass and paste high-temperature objects. Frequent and violent collision shall be avoided for the glass on the fire door and partition, and the frame fasteners and door closers shall be kept in good condition to ensure that the glass is always in a stable stress state.
Keep the frame drainage and ventilation dry: regularly clean the frame drainage holes and sealing strips to prevent dust and water from contacting the glass edge for a long time. For fireproof glass used in corridors, staircases and other parts, attention shall be paid to environmental ventilation to reduce the impact of moisture on the interlayer and sealing materials and extend the service life.
FAQ
How to choose the fire resistance rating of this sandwich fireproof glass? What is the configuration corresponding to different building parts?
The fire rating shall be determined according to the project specifications, installation parts and insulation requirements. When it is used for fire doors, corridor partitions, staircase windows and other parts, the required fire integrity and insulation level shall be determined, and then the number of glass layers, fire resistance interlayer and overall thickness shall be confirmed. When purchasing Wired Laminated Fire-Resistant Glass Panel, it is suggested to provide opening size, frame type and project location standard, which shall be evaluated and configured by the manufacturer, not only based on unit price or thickness.
Is there a fire test report or certification? How to check in foreign trade procurement?
The relevant fire test report or certification data can be provided according to the project requirements, and the specific standards shall be confirmed according to the destination country and the project requirements. During procurement, check whether the product structure, glass thickness, fire resistance rating, test direction and validity period in the report are consistent with the order, and confirm that the report covers the actual supply configuration. It is suggested that the certification requirements and acceptance standards be written into the contract before batch order is placed to avoid data inconsistency during customs clearance or project acceptance.
Are custom sizes, openings and profiled tooling supported? Can secondary cutting be done after compositing?
Supports customized dimensions, hole locations, notches and edge treatments per drawing, but related processing shall be completed before lamination of interlayers. Once laminated, fireproof glass shall not normally be cut, punched or edged, otherwise the fireproof layer and structural integrity will be damaged. Complete processing drawings shall be provided in advance during procurement to confirm hole location, edge treatment and dimensional tolerance. Sample or confirm the scheme before batch production to avoid installation failure after arrival.
How does packaging and transportation reduce the risk of damage? How to handle any damage or edge abnormality found during receiving?
Flameproof glass is usually packed with protective film, foam, wooden frame or wooden box. The corner and edge of fireproof layer shall be protected. The cabinet shall be fixed firmly to avoid extrusion and moisture. When receiving the goods, first check the state of the outer package and glass. In case of any damage, degumming, bubble or abnormal edge, take photos in time to retain the certificate and contact the sales personnel. Negotiate for reissue, claim for compensation or follow-up treatment according to the order agreement and trade terms. Edge sealing and drainage shall also be well done during installation to avoid long-term moisture of the fireproof layer.
50 meters south of the intersection of Road No. 7 and Yanfeng West Road, North Zone, High-tech Industrial Park, Ziya Economic and Technological Development Zone, Tianjin, China
If you have any enquiry about quotation or cooperation, please feel free to email us or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy